Product Details:
Payment & Shipping Terms:
|
Name: | Air Driven Double Diaphragm Pump | Application: | For High Temperature Liquid |
---|---|---|---|
Material: | Plastic | Color: | White |
High Light: | twin diaphragm pump,double acting diaphragm pump |
Plastic Air Driven Double Diaphragm Pump For High Temperature Liquid
Air Driven Double Diaphragm Pump Application
Industry: acid, alkali, solvent, suspended solids, decentralized system.
Petrochemical industry: crude oil, heavy oil, grease, mud, mud, etc.
Due to: resin, solvents, stain, paint, etc.
Chemical industry: detergent, shampoo, lotion, cream, hand cream, surfactant.
Ceramics, mud, ceramic slurry, lime, clay slurry.
Mining, coal slurry, magma, mud, mortar, powder slurry, lubricating oil etc.
Water treatment: lime, soft sediment, age, chemicals, waste water.
Industry: liquid and solid, chocolate, salt, vinegar, sugar, vegetable oil, soybean oil, honey, animal blood.
Beverage: yeast, syrup, concentrate, the mixture of gas and liquid, wine, fruit juice, corn starch, etc.
Air Driven Double Diaphragm Pump Features
1 |
Ceramic material for main valve and reversing valve ensures longer life, more stability and working in dirty compressed air ( most occasions, air filter become option). |
2 |
Without ice with the muffler. Innovative design with the exhaust space of the pump, some of muffler inside, this makes the air outlet smooth.) |
3 |
Outward parts of the pump are all die casted aluminum and special environment-protected painting, makes the pump with elegant appearance. |
4 |
Large flow capacity. Innovative design of chamber maximizes the flow capacity. Seamless adjustment with inlet valve, or even close the valve, without damaging the pump. |
5 |
Low consumption compressed air. Innovative design of the air flow system, minimizes the usage of compressed air to achieve maximum performance. |
6 |
Light and small size, movable. |
7 |
Modularization of main valve and air motor. No broken, easy to disassemble and repair. |
8 |
Optimized design greatly reduces overall component number of pump. Significantly improve performance, help for maintenance. |
9 |
For power variety, pneumatic pump’s flow capacity normally lowers than electric pump, but BSK pump is workable in series at certain conditions. This can largely satisfy customer request. |
10 |
Innovated design of sealing structure and material, totally solve the leakage inside or outside. |
11 |
BSK pump can be started with low air press ( only 1.5 KG air press can start BSK pump). |
Air Driven Double Diaphragm Pump Parameters
Air Inlet |
1/2-14NPTF-1 |
Fluid Outlet |
1-1/2-11-1/2NPTF-1,Rp1-1/2-11BSP |
Fluid Inlet |
1-1/2-11-1/2NPTF-1,Rp1-1/2-11BSP |
Max. Flow |
330L/Min |
Max. Head |
70M |
Max. Self-priming Lift (dry) |
4.5m |
Max. Air Pressure |
8.3bar |
Max. Particle Diameter |
6mm |
Max. Installation Dimension |
343×498×301mm |
Weight |
35kg |
Noise |
<80db |
Main Performance Parameters
No. Parameter Names Units Reference Values
1 Max. Working Air Pressure Mpa 0.83
2 Max. Flow l/min 330
3 Max. Head m 70
4 Max. Fluid Output Pressure Mpa 0.83
5 Max. Particle Through Diameter mm 6
6 Weight kg 19.5/2.5 ( PP/KV ) /35 (AL)/ 35(SS/CI)
7 Noise Level db <85
Maximum Applied Temperature Limits (diaphragm / ball / seal material)
Acetal ················································································40°- 150°F (4.4- 65.5°C)
Santoprene···················································································-40°- 225°F (-40°- 107.2°C) ························································································40°- 220°F (4.4°- 104°C) Nitrile··························································································10°- 180°F (-12°- 82°C) Viton······················································································-40°- 350°F (-40°-176.6°C) Hytrel···················································································-20°-150°F (-12°- 93°C) Kynar····················································································10°-200°F (-28.9°- 65.5°C) Polypropylene··········································································32°- 175°F (0-79.4°C)
OPERATING INSTRUCTIONS
Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
Disconnect the air supply from the pump if it is to be inactive for a few hours.
The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.
Contact Person: Mr. ALLSON