Send Message
Home
Products
Videos
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Company News
BOGEN PUMPS
Home ProductsAir Driven Double Diaphragm Pump

70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min

China BOGEN PUMPS certification
China BOGEN PUMPS certification
BA50 IS GOOD FOR NOW

—— work well

Good job, thank you for giving me a great vacation. Best Wishes, Vinod

—— Vinod Bernardo

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service

—— Mr Hussain

I'm Online Chat Now

70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min

70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min
70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min

Large Image :  70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min

Product Details:
Place of Origin: China
Brand Name: BOGEN
Certification: CE,EX
Model Number: 25-40SS-P99-A
Payment & Shipping Terms:
Minimum Order Quantity: 10 Unit(s)
Price: Negotiable
Packaging Details: Carton
Delivery Time: 2days
Payment Terms: FOB T/T
Supply Ability: 1000 Unit(s) Per Month
Guarantee:: one year
Detailed Product Description
Guarantee:: 12 Monthes Production: No Leakage Submersible Diaphragm Pump
Maximum Flow Rate: 378l/min Maximum Lift: 70m
Usage: Air Pump Feature: High Efficiency
High Light:

70m No Leakage AODD Pump

,

378L/Min AODD Diaphragm Pump

,

CE Certificated AODD Pump

70m Air Driven Double Diaphragm Pump No Leakage AOOD 378L/Min

 

Submersible Diaphragm Pump Introduction

 

The diaphragm pump offers high volume delivery even at low air pressure and a b road range of material compatibility options available.Refer to the model and option chart.The pump is provided with the modularized air motor and fluid section.

The air operated diaphragm pump alternately generates the intake fluid pressure and positive fluid pressure in the fluid chamber by using the pressure difference in the air chamber. The ball valve can ensure the forward flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres -sure and will stop cycling once maximum line pressure is reached (dis -pensing device closed) and will resume pumping as needed.

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

Submersible Diaphragm Pump Parameters

 

Item Description Unit Reference Figure
1 Maximum air inlet pressure Mpa 0.83
2 Maximum flow rate L/Min 378
3 Maximum lift M 70
4 Maximum outlet pressure Mpa 0.83
5 Maximum particle size mm 6
6 Weight kg 23
7 Noise level db <70

 

 

Submersible Diaphragm Pump application:

 

Pneumatic diaphragm pump is a new conveying machine, which is the novel kind of pump. Compressed air as the power source, it can be use in any corrosive liquid, liquid with particle, high viscosity, easy volatile, inflammable, highly toxic liquid.

 

 

A 2 5 X X - X X X - X   (model selection)

 

Form of pipe mouth:A-BSP B-NPT(F) C-Flange  

Diaphragm material:9 – Santoprene H – Hytrel   T - PTFE/Santoprene  

Ball material:9 -Santoprene H – Hytre T – PTFE A - Acetal  

Ball seat material:P/K –Polypropylene/Kynoar SS –Stainless Steel  

Pump material: SS –Stainless Steel AL –Aluminum Alloy   CI- Carbon Steel P/K –Polypropylene/Kynoar

 

 

 

 

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ···············································40°-         150°F        (4.4- 65.5°C)  

Santoprene·········································-40°- 225°F (-40°- 107.2°C)   ·················································40°- 220°F (4.4°- 104°C)   Nitrile··················································10°- 180°F (-12°- 82°C)   Viton···················································-40°- 350°F (-40°-176.6°C)   Hytrel··················································-20°-150°F (-12°- 93°C)   Kynar··················································10°-200°F (-28.9°- 65.5°C)   Polypropylene········································32°- 175°F (0-79.4°C)

 

 

 

Requirements for Air and Lubrication

 

 

70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min 0EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage.

  • A filter capable of filtering out particles larger than 50 microns should be used on the air supply. There is no lubrication required other than the “O” ring lubricant which is applied during assembly or repair.
  • If lubricated air is present, make sure that it is compatible with the “O” rings and seals in the air motor section of the pump.

 

 
 

OPERATING INSTRUCTIONS

 

  • Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
  • Disconnect the air supply from the pump if it is to be inactive for a few hours.
  • The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
  • When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
  • Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.

 

 

FLUID SECTION REASSEMBLY

 

  • Reassemble in reverse order.
  • Clean and inspect all parts. Replace worn or damaged parts with new parts as required.
  • Lubricate (23) diaphragm rod and 25) “Y” ring with grease.
  • Fix the diaphragm rod (23) with the auxiliary installation tool.
  • Prior to the final fastening of bolts and nuts, please determine whether the diaphragm (6A,6) is aligned with the fluid cap (5) properly to avoid the twisting of the diaphragm.
  • For the models using diaphragm: three rubber diaphragms (6) on the side, which are marked with AIRS SIDE "air chamber" are mounted in face of the pump body.
  • Start the pump, check the fastening and sealing after it runs for a period of time.

70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min 1

 

 

 

Disassembly of the Parts in Fluid Section

  a)First, remove the pump from the pipeline system and drain   off the materials from the pump inside.   b)Place the pump in a clean work environment.   c)Dismantle the outlet pipe (1) from the pump first, and then   take out the ball (2), O cup (3) and (47) and ball seat (4)   from the upper end of the fluid cap (5) in sequence. After   that, place the pump upside down and dismantle the inlet   pipe (11) so as to take out O cup (3) and (47), ball seat (4)   and ball (2) from the fluid cap (5).   d)Release the bolts around the two fluid caps to disassemble   the cap (5).   e)Release the diaphragm screw (10) and remove diaphragm   washer (7), (8) and diaphragm (6) from the both ends.   Remove the diaphragm rod (23) and the lip-shape seal   ring (25) can be replaced.   Disassembly of Parts for Air Valve   f)Loosen the bolt (39) first, and then dismantle the air valve   casing (38), air baffle (42) and sealing gasket (40), and   (41).   g) Take out the valve slice (36) and valve plate (37) from the   air valve casing (38).   h) Dismantle the circlip (29) and take out the limit end cap   (31) from both ends of the air valve casing (38), and you   can replace the cup (30) as needed.   i)You can check the lip-type packing (33) after pushing out   the spool (35) from the air valve casing (38) with the   hands.   Disassembly of Parts for Pilot Valve   j) Loosen 4 bolts (16) fixing the cylinder head first, and then   dismantle the cylinder head (14) and (18) on both ends and   remove the O cup (17).   k) Remove the sealing gasket (19) from the groove of the   motor casing (15).   l) Eject the pilot rod (22) and trigger rod (45) from the motor   casing (15) and you can replace the lip-type packing (20)   on the trigger rod or the O cup (44) on the pilot rod.   Reassembly of Diaphragm Pump   The reassembly steps of the pump are incompatible with   those of disassembly, so you are kindly asked to pay   attention to the following in the reassembly process:   1) All the sealing elements, as well as their contact parts,   must be greased.   2) Please check carefully prior to the use of all sealing   elements whether they are damaged, such as surface   damage. If damaged, please replace the new ones.   3) The lip direction of the lip-type packing (20)(, 25) and   (33) should be consistent with the direction shown in the   chart.   4) The bolts on the fluid cap should alternately be fastened   by opposite angles to achieve a better sealing result.      Troubleshooting   1. Some fluid is drained from the exhaust opening along   with the air flow.   Check the diaphragm for any damage.   Check the diaphragm screw for looseness   2. There are Air bubbles in the outlet fluid   Check the suction pipe connection for good sealing.   Check the connection between the suction pipe and the   intake manifold for good sealing.   Check the O ring between the intake manifold and the   fluid cap   Check the diaphragm screws for looseness   3. Low pump output   Check the air supply is stable.   Check the inlet/outlet for any blockage.   Check connectors connecting the intake manifold for air   tightness   Check that the ball is not stuck to the seat or the ball is   not improperly seated.   4. Air is discharged from the exhaust opening when there   is no reciprocating movement.   Check seal ring (33) on slid valve (35).   Check seal ring (20) on trigger rod (45).   Check seal ring (25) on diaphragm link rod.

70m Air Driven Double Diaphragm Pump No Leakage AODD 378L/Min 2

FAQ

 

1. Q: Are you a factory or trading company?

A: We are manufacturer in shanghai.

 

2. Q: What're your payments ?

A: T/T,Western Union,L/C etc.

 

3. Q: What about the package ?

A: Standard export plywood case or carton.

 

4. Q: How long is the warranty ?

A: We have 1 year warranty, except wearable parts.

 

5. Q: The use of products have?

A: The pump can suck the peanut, pickles, tomato slurry, red sausage, chocolate, hops and syrup etc.

 

The pump can suck the paint, pigment, glue and adhesive etc.

 

The pump can suck various glazed slurries of tile, porcelain, brick and chinaware etc.

Contact Details
BOGEN PUMPS

Contact Person: Mr. ALLSON

Tel: 008618122100289

Send your inquiry directly to us (0 / 3000)