Send Message
Home
Products
Videos
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Company News
BOGEN PUMPS
Home ProductsAir Operated Diaphragm Pump

Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch

China BOGEN PUMPS certification
China BOGEN PUMPS certification
BA50 IS GOOD FOR NOW

—— work well

Good job, thank you for giving me a great vacation. Best Wishes, Vinod

—— Vinod Bernardo

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service

—— Mr Hussain

I'm Online Chat Now

Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch

Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch
Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch

Large Image :  Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch

Product Details:
Place of Origin: China
Brand Name: BOGEN
Certification: CE
Model Number: BG25AL-P99-A
Payment & Shipping Terms:
Minimum Order Quantity: 10 Unit(s)
Price: Negotiable
Packaging Details: carton
Delivery Time: 15days
Payment Terms: FOB T/T
Supply Ability: 1000 Unit(s) Per Month
Guarantee:: one year
Detailed Product Description
Item: Pneumatic Diaphragm Pump Maximum Flow Rate: 192/Min
Fuel: Air Operated Weight: 12kg(Aluminum)
Color: Black
High Light:

Aluminium Alloy Air Operated Diaphragm Pump

,

Low Pressure Air Operated Diaphragm Pump

,

1 Inch Air Diaphragm Pump

Aluminium Alloy Sections Air Operated Diaphragm Pump Low Pressure 1 Inch Air Diaphragm Pump

Pneumatic Mining Low Pressure Diaphragm Pump With Butterfly Valves

 

The pneumatic diaphragm pump is a new type of conveying equipment and is the most
innovative pump in China. Using compressed air as the power source, for various corrosive
liquids, liquid with particles, high viscosity, volatile, flammable, highly toxic liquid, all of them
can be sucked up.
 
There are six specifications for diaphragm pumps. The inlet and outlet dimensions are 1/4′′,
1/2′′, 3/4′′, 1′′, 1.5′′, 2′′, 3′′, 4′′, and the fluid component materials are aluminum alloy, ductile iron,
polypropylene, stainless steel. According to different diaphragms and to meet the needs of
different liquid medias,the diaphragms materials are nitrile rubber, neoprene, polyethylene, three
rubber, polyether rubber, fluororubber, polytetrafluoroethylene, and polyvinylidene fluoride.

 

Low Pressure Diaphragm Pump Parameters

 

Item Description Unit Reference Figure
1 Maximum air inlet pressure Mpa 0.83
2 Maximum flow rate 1/Min 192
3 Maximum lift M 70
4 Maximum outlet pressure Mpa 0.83
5 Maximum particle size mm 3
6 Weight kg 12.3
7 Noise level db <70

 

 

Low Pressure Diaphragm Pump Main Advantages


1, Due to the use of air power, the flow automatically changed according to export resistance. Which is suitable for high viscosity fluid.
2, In inflammable and explosive environment, the pump is reliable and low cost, won't produce spark and not overheat,
3, The pump volume is small, easy to move, no foundation needed, convenient installation and economy. Can be used as mobile conveying pump.
4, Where there are dangers, corrosive materials processing, diaphragm pump can be separated completely with outside.
5, The pump shearing force is low, physical effect to medium is small, can be used for conveying unstable chemistry fluid.

 

The working principle of the pneumatic diaphragm pump: in the two symmetric working
chambers of the diaphragm pump, each is equipped with a flexible diaphragm. The connecting rod
connects the two diaphragms into one body, and the compressed air enters the intermediate body
from the inlet joint of the pump and pushes the diaphragm in the two working chambers and
drives the diaphragms of the connecting rods to move synchronously. At the same time, the gas in
the other working chamber exits the pump from the back of its diaphragm. When the piston
reaches the end of the stroke, the valve mechanism automatically draws the compressed air into
another chamber, pushing the diaphragm pump to move in the opposite direction, thus forming a
synchronous reciprocating motion of the two diaphragms. Two one-way ball valves are arranged
in each working chamber, and the reciprocating motion of the diaphragm causes a change in the
inner volume of the working chamber, forcing the two one-way ball valves to alternately open and
close, thereby continuously inhaling and discharging the liquid.
The most obvious difference between pneumatic diaphragm pumps and other diaphragm
pumps is the distributing valve structure. The pneumatic diaphragm pump valve structure cancels
the distributing valve of traditional "O" ring and cylindrical valve structure. Three - way pilot is
adopted to eliminate valve dead point and pump shutdown phenomenon. Providing proper and
reliable reversing signals to avoid downtime and faster reversing for greater pump flow, providing
delivery performance for smaller pulses and more stable flow.
The pneumatic diaphragm pump uses a simple and highly reliable air reversing valve to
ensure no downtime to avoid costly shutdown costs. All air valve components can be replaced
without disassembling the part of fluid. The aluminum parts are specially treated to resist
corrosion from dirty air. The plastic material of sliding block in the reversing valve is strong and
 
 

Troubleshooting guidance

1.Air outlet has fluid when pumping

 Check if the diaphragm be damaged

 Check if the diaphragm bolts loosening

2.The output fluid has bubble

  Check the suction pipe joints are well sealed

  Check the suction pipe and fluid inlet are well sealed

  Check the ring between fluid inlet and fluid cap are with O-ring

  Check the diaphragm bolts are fastened

3.Pumping capacity is low

  Check if the air supply is stable

   Check whether the inlet and outlet is blocked

   Check the joint to the fluid inlet is sealed and not leakage

   Check if the ball stick to the ball seat or ball seat is not suitable

4.  Without reciprocating motion, the air flow is discharged from the exhaust port

    Check the sealed ring of the main air valve

    Check the sealed ring of the pilot rod valve

    Check the sealed ring of the diaphragm rod

 